2016 AIChE Spring Meeting – April 11-14, 2016 – Houston, TX

## Project Background

- Existing burners: conventional raw gas burner
- Average yearly NOx level: 244 ppmv [500 mg/Nm3]
- Heater roof tubes are 16.4 ft above furnace floor 
    - Existing burners were impinging on roof tubes causing hot spots and tube coking
- Poor combustion air distribution to burners

## GLSF Round Flame Minimum Emissions Burner

Chosen for its ability to achieve ultra-low NOx emissions while maintaining compact flame shapes and high flame stability on all fuels

## Conclusions

- Multi-Burner combustion testing was performed in Zeeco’s Testing Facility to accurately simulate on site conditions
- Burners were delivered to site and installed with Zeeco’s supervision
- On site burner performance testing was conducted and proved that the burners were meeting all required performance goals
- Further heater operation improvements can be performed to improve the burner performance even further

[Download Presentation](https://www.zeeco.com/hubfs/Zeeco-En_June_2020/pdf/Zeeco-2016-AICHE-PPT.pdf)

[View full post](https://www.zeeco.com/resources/presentations/low-nox-burner-retrofit-challenge)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Ryan Roberts"
  },
  "dateModified" : "2023-11-07T22:06:40.147Z",
  "datePublished" : "2016-04-12T21:18:00Z",
  "headline" : "Low NOx Burner Retrofit Challenge",
  "image" : {
    "@type" : "ImageObject",
    "height" : 428,
    "url" : "https://info.zeeco.com/hubfs/GLSF-round-flame-featured-image.jpg",
    "width" : 855
  },
  "mainEntityOfPage" : "https://www.zeeco.com/resources/presentations/low-nox-burner-retrofit-challenge",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60,
      "url" : "/hs/hsstatic/content_shared_assets/static-1.4092/img/default-amp-logo.png",
      "width" : 60
    },
    "name" : "Presentations"
  }
}
```